3600W Selectronic 48V Pure Sine Wave Inverter SA42
The Selectronic SA42 sine wave inverter comes with many features not normally found in other inverters. An illuminated display on the front panel allows you to tailor your inverter to suit your needs, perform diagnostics, and take vital readings; no compromises needed. As if this is not enough, you also have the ability to upgrade to ENERGY MANAGEMENT Mk II as your needs develop. As you can see, there is now no need to limit the ability of your power system by the inability of your inverter.
No Compromise All the vital parameters of the SA42 are fully adjustable making it compatible with any remote power system. These parameters are easily changed as required via the front panel which has an illuminated display to tell you what is being adjusted. No need to compromise your power system performance. Of course, all the settings are retained when the inverter is powered down.
Displays The display on the front panel of the SA42 gives you vital information about your power system. You are able to display INVERTER STATUS, AC VOLTS, AC AMPS and BATTERY VOLTS. Also the SA42 will alert you to the cause of any inverter shutdown by beeping an alarm and displaying a message containing the reason for the shutdown. As a shutdown occurs, the SA42 stores the cause of the shutdown in an ‘Alarm Log’ allowing you to view at a later date the cause of up to the last one hundred inverter shutdowns. The SA42 will shutdown and protect itself if the battery volts are too high or too low, the load on the inverter is too high, or the temperature of the inverter becomes too high. A set of diagnostic readings can also be accessed to assist in remote troubleshooting.
Safety and Standards At Selectronic, we are serious about your safety so we have built the SA42 to conform to the Australian standards AS3100 and AS3108 (for electrical equipment and isolating transformers). This means the SA42 can be safely integrated into any normal electrical system. Naturally the SA42 conforms to the requirements of the Electromagnetic Compatibility framework (C tick), which means low radio frequency interference.
Simplicity Whilst the SA42 is a very sophisticated inverter, it does not require complex programming. In most cases the SA42 will perform perfectly well with the factory settings. Just connect it up, switch on and your power problems have disappeared.
Modular Construction This important feature of the SA42 allows for quick and easy on site repairs by any authorised person. Inconvenient down time is minimised.
Fully Upgradable Don’t lock yourself into an inverter that cannot expand with your remote power system needs. As your finances allow or as your needs change, the SA42 can be upgraded to Energy Management Mk II. This system is a fully featured monitoring and control system that allows you to keep track of vital system parameters, perform control functions and allow remote communication. SA42 models which include the EM Mk II fitted ex factory are also available.
Applications
The SA42 is so versatile it can provide the user with a source of independent power for virtually any application. Applications include:
· Home
· Boats
· Caravans
· Motor homes
· Tradesman
· Business applications
|
Includes Energy Management Mk II
|
|
Extra features included in this option over the original Energy Management are:
· Four control outputs.
· Replacement of interface board with covered plug in screw terminals.
· Fully adjustable Solar regulator controller option.
· Automatic zero point setting for percentage charge in battery.
· Automatic battery efficiency compensation.
· Load profile logging.
· Modem interface output for remote control of inverter and system via modem & remote computer.
SELECTRONIC SA42 INVERTER SPECIFICATIONS
ELECTRICAL |
PARAMETER |
SA42 Inverter |
CONDITION |
|
Output Power @ 25 deg C Ambient |
|
Max Continuous 1/2 Hour Rating Max Surge |
|
Output Power @ 40 deg C Ambient |
|
Max Continuous 1/2 Hour Rating Max Surge |
|
Voltage Input Range |
|
Range |
|
Input Current |
0.05A DC 0.40A DC 78A DC 210A DC |
Stand By Inverter ON - No Load Max Continuous Max Surge |
|
Demand Start Sensitivity Response Time |
|
User Adjustable |
|
Low Voltage Shutdown |
|
User Adjustable |
|
High Voltage Shutdown |
|
User Adjustable |
|
Output Voltage |
Adjustable from 220 to 240V AC +/- 4% |
@ Nominal DC Input, No Load to Full Load |
|
Output Current |
|
Max Continuous Max Surge |
|
Output Wave Shape Output Frequency Total Harmonic Distortion |
True Sine Wave 50Hz +/- 0.01% < 4% |
|
Power Factor Limitations |
|
|
Efficiency |
|
|
Time to Shutdown |
|
|
Input/Output Isolation |
1875 V AC |
|
Memory Retention |
Permanent |
|
Operating Temperature Range |
-10 ° to 50 ° |
|
Conforms to standards |
AS3100 (wiring), AS3108, AS1044 (EMC), C tick |
MECHANICAL
|
|
Size |
500mm wide x 180mm high x 370mm deep |
|
Weight |
29kg |
|
Weight Packed |
32kg |
|
Input Lead Length |
1.5 metres |
|
Output Wiring Method |
Rear three terminal junction box with conduit knock outs |
|
Output Socket |
Dual switched GPO |
|
Chassis |
Powder coated zinc steel (Wedgwood Blue) |
|
DC Isolation |
Single Pole Circuit Breaker |
|
Warranty |
5 year parts and labour (Conditions apply) |
|